LPRO-P16 Series Reverse Osmosis System

    have been engineered for capacities ranging from 1200GPD to 9000GPD for low TDS feed water design (Feed TDS < 1500ppm)


    Applications:

    ● Drinking water

    ● Food & Beverage

    ● Electroplating

    ● Power plant

    ● Preparation of medicine

    ● Petrochemical industry

    ● Eyeglass

    ● Waste water reuse

    ● Metallurgy

    ● Pretreatment of EDI or Mixed Bed


  • Parameters

    have been engineered for capacities ranging from 1200GPD to 9000GPD for low TDS feed water design (Feed TDS < 1500ppm)


    Applications:

    ● Drinking water

    ● Food & Beverage

    ● Electroplating

    ● Power plant

    ● Preparation of medicine

    ● Petrochemical industry

    ● Eyeglass

    ● Waste water reuse

    ● Metallurgy

    ● Pretreatment of EDI or Mixed Bed


Quick Details


Place of Origin: Fujian, China             Brand Name: PTK                           Model Number:  LPRO-P16

 

Capacify: 1200-9000GPD                  Membrane quantity: 1-6 pc              Feed water TDS: <1500ppm


Benefits


Fully Equipped and Customizable
Expandable and Skid Mounted
Components Easily Accessible 

Pre-Plumbed Wired and Assembled                    
Individually Tested and preserved
Low Operation and Maintenance Costs
Easy Maintenance and Servicing

1-Year Limited Warranty


Standard Features


 

Cartridge Filtration

 Housing --- 4.5" ×20"  

 Sediment filter --- 4.5" ×20"; 5micron

 Quantity --- 2 pcs


Membrane Elements and Housings

 Membrane model ---LP21-4040   

Membrane manufacturer --- Vontron

Membrane rejection --- 99.0-99.6%

 Housing Spec. --- FRP, 450psi, Side port


Boost Pump

 Type --- Vertical Multi-stage Centrifugal                       

 Pump Material --- SS304

 Connection --- DIN Flange

 Pump Brand --- CNP



Control system

Siemens PLC

 Parameters setting panel

 Parameter setting panel

 Tank level control

 Low pressure/High pressure protection

 Auto flush

 Pretreatment lockout control backup

 

Documentation Included

 Operation and maintenance manual

 Drawings: P&ID, Electrical diagram


Options and Upgrades

PH Meter

Feed Water Conductivity Meter         

Grundfos Pump 

Communication: Modbus RTU
SS304 Seamless Housing
Anti-scalant Dosing System
Clean-in-Place (CIP) system

Pretreatment system


Specifications



MODEL

LPRO-P16-1500

LPRO-P16-3000

LPRO-P16-4500

LPRO-P16-6000

LPRO-P16-9000

Feed Water TDS ¹ 

Nominal Permeate rate ²

Approximate Concentrate rate 

Approx. conc. recycle rate

Approx. Feed rate 

Recovery Rate

<1500ppm

0.25m³/hr

0.12m³/hr

1.1m³/hr

0.38m³/hr

50~75%

<1500ppm

0.5m³/hr

0.25m³/hr

0.8m³/hr

0.7m³/hr 

50~75%

<1500ppm

0.75m³/hr

0.3m³/hr

0.8m³/hr

1.0m³/hr 

60~75%

<1500ppm 

1.0m³/hr

0.4m³/hr

0.6m³/hr

1.5m³/hr 

60~75%

<1500ppm 

1.5m³/hr

0.6m³/hr

0.6m³/hr

2.2m³/hr 

60~75%

Membranes Elements and Housings

Membranes quantity 

Housing quantity

1

1 (single element)

2

2 (single element)

3

3 (single element)

4

4 (single element)

6

6 (single element)

Membrane housing array

 1

 1→1

1→1→1

1→1→1→1

1→1→1→1→1→1

¹Treatment ability and working pressure of the RO system are dependent on feed water quality.

² Maximum permeate rate listed at temperature 25, Permeate rate will decreases with decreasing temperature

Order Example

LPRO-P16

9000

TB

220S50

Type

Nominal Capacity (GPD)

Connection (code)

Power supply (code)


Connection Port

Code

Thread,BSPT

TB

Thread, NPT

TN



 

Power Supply

Code

220VAC / 50hz / single phase

220S50

230VAC / 50hz / single phase

230S50

240VAC / 50hz / single phase

240S50

100VAC / 60hz / single phase

100S50

110VAC / 60hz / single phase

110S50

120VAC / 60hz / single phase

120S60

127VAC / 60hz / single phase

127S60

200VAC / 60hz / single phase

200S60

220VAC / 60hz / single phase

220S60

240VAC / 60hz / single phase

240S60

380VAC / 50hz / three phase

380T50

400VAC / 50hz / three phase

400T50

415VAC / 50hz / three phase

415T50

440VAC / 50hz / three phase

440T50

200VAC / 60hz / three phase

200T60

208VAC / 60hz / three phase

208T60

220VAC / 60hz / three phase

220T60

240VAC / 60hz / three phase

240T60

380VAC / 60hz / three phase

380T60

440VAC / 60hz / three phase

440T60

460VAC / 60hz / three phase

460T60

480VAC / 60hz / three phase

480T60

LPRO-P16 Series Reverse Osmosis System
Long press to look detail
Long by picture save/share
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully

LPRO-P16 Series Reverse Osmosis System

INQUIRY
INQUIRY

enquiry form:

  • Please enter the verification code

Inquiry Content:


You have no items to require

Add Successfully

LOCATION:

No.6 Zijin Road,Fujian Shaowu Economic Development Zone Shaowu city, Fujian 354000, China

CONTACT US:

Phone:+86-599-6303876

Fax:+86-599-6303816

Email: sales@fjptk.com

              amy.chen@fjptk.com

Scan code to follow us

Scan code to follow us

Copyright ©  fujian ptk water technologies co., ltd. All rights reserved. 闽ICP备19004147号-1

Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.